| Tracware 2001 belongs to a set of software
utilities designed to be used with Chemtracs PC
2400 D Particle Counters. It offers data collection and
monitoring capabilities in a user-friendly graphical interface.
Tracware includes real-time and historical data retrieval,
as well as an alarm screen, a configuration utility, and
a communication utility. Reporting features have been
designed for quick access, while still having the capability
to customize individual report setups. Tracware 2001 was
designed to allow for easy retrieval of historical information
such as particle count data, auxiliary inputs, status
information, and alarm events. Tracware is part of a suite
of software packages (DDE Server, an OPC Server, and a
Serial Communication Protocol Utility). |
|
 |
 |
|
STANDARD FEATURES
|
| Chart/Lists Up to eight chart/lists,
with eight tags per graphs, can be displayed at one time
in the main window. |
| Sensor Screen
Use the sensor screen to view current particle counts,
flow, cell, noise, alarms, and auxiliary inputs for each
configured sensor. |
| Reporting The
reporting screen allows the user to easily configure and
report on any set of particle count data. The user can
select historical date/time in a configured report, then
view a preview of the report on the screen. The user can
also define reporting parameters to eliminate or include
data, and also add calculation totals to the report. |
| Status Pane - The status view is
located on the bottom of the main window. This view displays
system information as well as communication information.
If a particle counter fails to communicate or a data file
does not exist for a particular date, a status message
will appear in this view. A date field allows the user
to retrieve a previous days status. This window can be
hidden from the main screen. |
|
| Navigation Window
The navigation window gives the user the ability to easily
pull up any program screen. This feature is useful if
multiple windows are being displayed on top of each other.
|
| Sensor Screen
Use the sensor screen to view current particle counts,
flow, cell, noise, alarms, and auxiliary inputs for each
configured sensor. |
| Configuration
The setup window allows the operator to easily configure
system settings, sizes, alarms, graphs, and removal calculations. |
| TracComm Communication
utility allows for setting addresses, verifying communication,
and scanning for sensors. Polling the displayed sensor
will show current count data, auxiliary inputs, and various
particle counter settings. |
|
 |
|
GENERAL SPECIFICATIONS
|
| Operating Systems: |
Windows 95/98/ME/NT/2000/XP |
| Communication Protocol: |
Modified Optomux Opto 22 |
| Viewable Windows: |
Up to 8 |
| Size Channels:
|
Up to 8 configurable |
| Composite Size Channels: |
Up to 4 configurable
Total of 8 (size + composite) |
| Sample Period: |
15 seconds/minute |
| Sample Frequency: |
60 seconds |
| Number of Sensors: |
Up to 96 |
| Alarms: |
Particle Counts, Auxiliary
Inputs, Flow, Cell Condition |
| Configurable Charts: |
Unlimited |
| Auxiliary Inputs: |
4 Inputs per Particle Counter
(4-20 mA) |
| Trends: |
Up to 8 per chart/list |
| Export Types: |
Up to 15 different file formats |
| Chart Formats: |
2D/3D |
| Report Types: |
List, Summary, Chart |
| |
|
SYSTEM REQUIREMENTS
|
|
> Windows 32-bit Operating System
(95/98/NT/2000/XP)
|
|
> Pentium III 800Mhz Processor
Minimum - Pentium II 266Mhz
|
|
> 128MB RAM
Minimum - 32MB RAM
|
|
> 200MB Available Hard Drive Space
Minimum - 40MB Hard Drive Space
|
|
> Available Serial Communications
Port
|
|
> 1024 x 768 Screen Resolution
Minimum - 800 x 600 pixels
|
| |
|